Power Cable
BPYJVXLPE Variable Frequency Cable
Shielded copper power cable for connections between variable-frequency drives and motors. XLPE insulation, a copper-wire braid and a PVC sheath form the submitted construction.
- Core configuration
- 3+3 symmetrical / 3-core / 4-core
- Cross-section range
- 1.5–300 mm²
- Insulation / sheath
- XLPE / PVC
01 / Product details
Construction & features
- Symmetrical 3+3 construction option
- Copper-wire braided shield
- XLPE insulation with PVC outer sheath
01
Conductor
Class 2 stranded copper
02
Insulation
XLPE
03
Shield
Copper-wire braid; coverage to be confirmed
04
Outer protection
PVC
02 / Specification reference
Technical parameters
Model-level information for quotation and comparison. Core count and cross-section ranges do not imply that every combination is available.
| Model | BPYJV |
|---|---|
| Product family | Power Cable |
| Conductor | Class 2 stranded copper |
| Core / pair configuration | 3+3 symmetrical / 3-core / 4-core |
| Nominal cross-section range | 1.5–300 mm² |
| Insulation | XLPE |
| Outer sheath | PVC |
| Shield / pair structure | Copper-wire braid; coverage to be confirmed |
| Rated voltage | Request the approved rating for your selected construction |
| Continuous conductor temperature¹ | 90°C |
| Short-circuit temperature¹ | 250°C · maximum 5 seconds |
| Minimum laying temperature¹ | 0°C |
| Minimum bend radius¹ | 15D |
| Applicable standards & certificates | Confirm the required standard and review original supporting documents before ordering |
| Fire / weather performance | Project-specific requirement; no grade is declared without verification |
03 / Typical requirements
Applications
- Variable-frequency drive and motor connections
- Fan and pump drive systems
- Industrial speed-control equipment
Share the installation environment and required performance so the technical team can confirm suitability for your project.
04 / Supply information
Packaging & ordering
- Packaging
- Coil / soft packaging for smaller sizes; wooden drums for larger sizes. Confirm length per coil or drum with your order.
- Indicative MOQ
- 3,000 m for smaller sizes; 1,000 m for larger sizes. Exact size thresholds and order quantities are subject to quotation.
- Samples
- 10 cm sample sections can be requested; other lengths and sample arrangements are agreed with sales.
- Quotation basis
- FOB terms can be discussed. Confirm conductor-metal pricing, quotation validity and the named port with sales.
- Availability & lead time
- Check stock or a production schedule for the selected model, size and quantity. Delivery is confirmed in the quotation.
- Order details
- Model, cores / pairs, cross-section, voltage requirement, applicable standard, quantity, packing length and destination.