RVS Twisted Pair Flexible Wire
RVSProduct photograph · open for full size ↗

Building Wire

RVSTwisted Pair Flexible Wire

Two PVC-insulated flexible copper conductors twisted together without an outer sheath. RVS connecting wire is offered for indoor lighting, doorbell, broadcast and alarm-system connection requirements.

Core configuration
2 cores · 1 twisted pair
Cross-section range
0.5–2.5 mm²
Insulation / sheath
PVC / None · insulated twisted-pair wire

01 / Product details

Construction & features

  • Class 5 fine-stranded copper conductors
  • Two-core twisted construction without a sheath or shield
  • Paired insulation colors for conductor identification
  • Submitted cross-section range: 0.5–2.5 mm²
01

Conductor

Class 5 flexible copper

02

Insulation

PVC

03

Shield

Unshielded twisted pair

04

Outer protection

None · insulated twisted-pair wire

02 / Specification reference

Technical parameters

Model-level information for quotation and comparison. Core count and cross-section ranges do not imply that every combination is available.

¹ Temperature and bend-radius values are reference data from the submitted product sheet, subject to confirmation. D denotes overall cable diameter (insulated-wire diameter for unsheathed wire). Use the approved technical datasheet for selection and installation.
ModelRVS
Product familyBuilding Wire
ConductorClass 5 flexible copper
Core / pair configuration2 cores · 1 twisted pair
Nominal cross-section range0.5–2.5 mm²
InsulationPVC
Outer sheathNone · insulated twisted-pair wire
Shield / pair structureUnshielded twisted pair
Rated voltageRequest the approved rating for your selected construction
Continuous conductor temperature¹70°C
Short-circuit temperature¹160°C · maximum 5 seconds
Minimum laying temperature¹0°C
Minimum bend radius¹2D
ColorsPaired colors, including red / black; other combinations by agreement
Applicable standards & certificatesConfirm the required standard and review original supporting documents before ordering
Fire / weather performanceProject-specific requirement; no grade is declared without verification

03 / Typical requirements

Applications

  • Indoor lighting connections
  • Doorbell and broadcast connections
  • Alarm and smoke-detector connections · confirm system requirements

Share the installation environment and required performance so the technical team can confirm suitability for your project.

04 / Supply information

Packaging & ordering

Packaging
Coil / soft packaging for smaller sizes; wooden drums for larger sizes. Confirm length per coil or drum with your order.
Indicative MOQ
3,000 m for smaller sizes; 1,000 m for larger sizes. Exact size thresholds and order quantities are subject to quotation.
Samples
10 cm sample sections can be requested; other lengths and sample arrangements are agreed with sales.
Quotation basis
FOB terms can be discussed. Confirm conductor-metal pricing, quotation validity and the named port with sales.
Availability & lead time
Check stock or a production schedule for the selected model, size and quantity. Delivery is confirmed in the quotation.
Order details
Model, cores / pairs, cross-section, voltage requirement, applicable standard, quantity, packing length and destination.
WA